√ High-efficiency energy transmission, precise treatment
√ Durable and durable, suitable for surgical conditions
√ Sterile fit, easy to use
| Designed specifically for microwave therapy surgery, its core purpose is to connect microwave therapy devices and surgical probes, enabling precise microwave energy transmission and temperature/impedance signal feedback from the surgical area. |
Designed specifically for microwave therapy surgery, its core purpose is to connect microwave therapy devices and surgical probes, enabling precise microwave energy transmission and temperature/impedance signal feedback from the surgical area. It is suitable for medical scenarios such as tumor ablation, tissue coagulation, and minimally invasive surgery. The cable utilizes medical-grade biocompatible materials, a high-temperature resistant insulation structure, and a low-loss transmission conductor. Combined with sterile sealed connectors and surgical-specific accessories, it features resistance to disinfection and bending, insulation safety, and distortion-free signal transmission. It can withstand the stringent requirements of high-frequency microwave radiation, repeated disinfection, and minimally invasive procedures during surgery, making it a core medical connection component ensuring the precision and safety of microwave therapy.
|
Item
|
Specification Details
|
|
Applicable Scenarios
|
Microwave therapy scenarios such as tumor ablation surgery, tissue coagulation surgery, minimally invasive surgery, and interventional therapy
|
|
Core Purpose
|
Energy transmission between microwave therapy equipment and surgical probes; Temperature/impedance signal feedback
|
|
Compatible Equipment
|
Mainstream brand microwave therapy devices (Medtronic, Kangpuwo, Mindray, Johnson & Johnson, etc.); Compatible with minimally invasive probes (1.8mm/2.4mm, etc.)
|
|
Operating Frequency
|
2450MHz (Mainstream) / 915MHz (Optional)
|
|
Rated Power
|
0~120W (Adapts to different treatment intensity requirements)
|
|
Cable Specification
|
Energy Wire: 26AWG~22AWG Silver-plated Copper Conductor (Conductivity ≥99.5%); Signal Wire: 30AWG~28AWG Tinned Copper Conductor
|
|
Insulation/Sheath Material
|
Insulation Layer: PTFE (High-temperature Resistant); Sheath: Medical-grade Silicone/PU (Biocompatibility Class VI)
|
|
Shielding Structure
|
Silver-plated Copper Mesh Shield (Coverage Rate ≥95%) + Foil Shield, reducing electromagnetic interference
|
|
Connector/Terminal Type
|
Medical-grade Sterile Sealed Connectors, Quick-connect Foolproof Terminals; Contact Resistance <0.5mΩ
|
|
Protection Performance
|
Sterilization Resistant (High-temperature & High-pressure / EO / Alcohol); Water-resistant IPX7 (Connectors); Microwave Radiation Resistant
|
|
Safety Certifications
|
ISO 10993, GB 9706.1, CE MDR, FDA 510(k), RoHS
|
|
Included Accessories
|
Sterile Packaging, Anti-tangle Storage Tube, Sterilization Guide Card, Connector Protection Cover, Compatibility Adapter Gasket
|